what purpose ?

Overview

EZContrast Series allow to measure viewing angle luminance and color data.

 

This system provides accurate color measurement for any type of stimulus. ELDIM is manufacturing on its own all the key components of its system, including optics thanks to advanced technologies.

 

The full viewing cone is measured with high incidence and azimuth angular resolution within seconds for luminance and chromaticity and minutes for radiance.

Features

  • Non-contact viewing angle measurement
  • High color accuracy
  • Resolution: 0.04°/CCD pixel
  • Cooled sensor

Applications

  • Viewing angle analysis for QC or R&D
  • Viewing angle polarization as add-on
  • Large spot size for W series (6mm)

More details

Technical features

SpecificationsEZContrast L80EZContrast L80WEZContrast XL80EZContrast XL80W
Field coverageIncident angle
Azimuth angle
0-80°
0-360°
0-88°
0-360°
Measuring AreaMaximum diameter
Minimum diameter
2mm

100μm
6mm

300μm
2mm

100μm
6mm

500μm
Optimum distanceEnsure light coming from same spot at any angle3.7mm2.5mm1mm
AccuracyLuminance
Chromaticity (x,y) RMS
Stokes vector with band pass filter (option)
±3%

0.002

±3%
PerformancesPeltier cooled grade 1
Angular resolution
A/D converter
Angular optical Resolution

Yes

0.08°/ccd pixel

14-16 bits

±0.3°(*)
Yes

0.04°/ccd pixel

14-16 bits

±0.2°(*)
Yes

0.09°/ccd pixel

14-16 bits

±0.3°(*)
Yes

0.05°/ccd pixel

14-16 bits

±0.2°(*)
ChromaticityColor Filters
Additional Filters
Yes
Optionnal
Yes
Not available
Yes
Optionnal
Yes
Optionnal
Measurement ModesLuminance
Chromaticity
Polarization (option)
Radiance spectrum on axis (option)
Yes

Yes

Yes, Auto

Yes, Auto
Yes

Yes

No

Yes, Auto
Yes

Yes

Yes, Auto

Yes, Auto
Yes

Yes

No

Yes, Auto
Luminance RangeMinimum (cd/m2)
Maximum with density (option)
0.001

1 000 000
0.001

500 000
0.001

1 000 000
0.001

1 000 000
Short-term repeatabilityLuminance
Chromaticity (x,y) RMS
Stokes vector (option)
±0.02%

0.001

±0.5%
Polarizing elementsFor polarization measurements3 pol , 2WPAutomatedNot available3 pol , 2WPAutomatedNot available
Reflective optionsCollimated & diffused Only DiffusedNot availableAvailableNot available
Spectro radiometer optionMeasurement on axis for self calibrationAvailable
Spot viewerFor position adjustment Color CMOS camera, USB 2.0 interface
Use conditionsTemperature range standard
Temperature range (option)
Humidity range (non condensing)
0 to 30°C

-40 to 80°C

0 to 85%
Specifications can be changed without notice